    ComponentProportionNotes
    Powder: OPC 42.540%Component A
    Powder: fine silica sand 0.1–0.3 mm57%Dried
    Powder: additives (HPMC, defoamer)≈ 3%
    Liquid: acrylic / SBR polymer emulsionPowder : Liquid = 3 : 1 by weightComponent B
    Consumption1.5 kg/m² per coat, 2 coats≥ 2 mm total dry film

    Mixing & application

    1. Remove laitance, oil and loose material; fill cracks and form 50 mm cement fillets at wall–floor joints.
    2. Saturate the surface with water; leave damp with no standing water.
    3. Add powder slowly to the liquid and mix 3 minutes with a slow drill to a lump-free slurry.
    4. Apply the first coat by brush in one direction; embed fibre-glass mesh at corners and joints.
    5. Apply the second coat at right angles after 4–6 hours.
    6. Cure with damp hessian for 3 days; do a 48-hour ponding test before screed/tiles.

    Acceptance criteria

    • No leakage after 48-hour ponding test.
    • Dry film thickness ≥ 2 mm, no pinholes.

    Health & safety

    • Wear PPE: helmet, safety shoes, gloves and eye protection.

    FAQs

    What is the Cementitious Waterproofing (Two-Component) Recipe used for?

    Polymer-modified flexible cementitious coating for bathrooms, water tanks, basements and terraces under screed or tiles.

    Which standard does it follow?

    It is based on EN 14891, ASTM D4541 (pull-off). Always follow your project specification where it differs.

    Can I print or submit this?

    Yes. Use Print / PDF, add your project details and submit it through your normal approval process. Get it reviewed by your engineer or consultant first.

    Is it free?

    Yes. The library is free to read and print, without an account.

    General guidance only, not engineering advice. Project specifications, approved drawings, manufacturer data sheets and your consultant's instructions take priority. See our Policy. This document was generated using CM PRO. Powered by CM PRO.

    Related guides