Geotechnical & Soil calculator

    SPT N-Value Correction (N60 & (N1)60)

    The free SPT N-Value Correction (N60 & (N1)60) by CM PRO helps site engineers, quantity surveyors, contractors and homeowners corrects field SPT blows for hammer energy, rod length, borehole and overburden; estimates φ, relative density and allowable pressure. It supports both metric and imperial units and gives instant results for turning raw borehole log blow counts (ASTM D1586) into corrected N values for foundation design checks and soil investigation reviews.

    How the SPT N-Value Correction (N60 & (N1)60) works

    N60 = N × (ER ÷ 60) × CB × CS × CR. σ′v = γz − γw(z − zw). CN = √(100 ÷ σ′v) ≤ 1.7 (Liao & Whitman). (N1)60 = CN × N60. φ = √(20 (N1)60) + 20 (Hatanaka & Uchida). Dr = √((N1)60 ÷ 60) (Skempton). Allowable pressure for 25 mm settlement by Bowles (Meyerhof).

    How to use this calculator

    1. Sign up free and verify your email to unlock the calculator.
    2. Choose Metric (m, mm, m³, kg) or Imperial (ft, in, cft, lb) units.
    3. Enter the field spt blows (n), hammer energy ratio, test depth below ground, water table depth, soil bulk unit weight, borehole diameter, sampler, footing width b (for allowable pressure), footing depth df.
    4. Results update instantly — read the quantities in the Results panel.
    5. Add a wastage allowance and confirm against your drawings and specifications before ordering.

    Typical uses

    Turning raw borehole log blow counts (ASTM D1586) into corrected N values for foundation design checks and soil investigation reviews.

    Assumptions & limitations

    Results are planning estimates based on standard assumptions for geotechnical & soil work. They do not replace structural design, site measurement or project specifications. Material densities, wastage and mix proportions vary by region and supplier.

    Frequently asked questions

    How does the SPT N-Value Correction (N60 & (N1)60) work?
    N60 = N × (ER ÷ 60) × CB × CS × CR. σ′v = γz − γw(z − zw). CN = √(100 ÷ σ′v) ≤ 1.7 (Liao & Whitman). (N1)60 = CN × N60. φ = √(20 (N1)60) + 20 (Hatanaka & Uchida). Dr = √((N1)60 ÷ 60) (Skempton). Allowable pressure for 25 mm settlement by Bowles (Meyerhof).
    Can I use the SPT N-Value Correction (N60 & (N1)60) in feet and inches?
    Yes. Switch to Imperial and enter feet, inches, square feet or pounds — the calculator converts automatically and shows results in imperial units.
    When should I use the SPT N-Value Correction (N60 & (N1)60)?
    Turning raw borehole log blow counts (ASTM D1586) into corrected N values for foundation design checks and soil investigation reviews.
    Is this construction calculator free?
    Yes. All CM PRO construction calculators are free — you only need to sign up and verify your email.

    Related searches: SPT N value correction calculator, N60 calculator, (N1)60 overburden correction, SPT to friction angle, ASTM D1586 calculator.

    Also try these tools

    Run your whole site with CM PRO ERP